● Measurement: 3-phase AC kWh, kVarh, U, I, P, Q, S, PF, F and etc
● Accuracy: 0.5% (kWh)
● Frequency: 45~65Hz
● Rated Voltage: 3x380~456Vac L-L (direct connect); 3x100~120Vac L-L (via PTs)
●Rated Current: 3x10(80)A AC (direct connect); 3x1(6)A AC (via CTs)
● Communication: RS485 (MODBUS-RTU)
● Multi-rate: 4 Tariff Rates and etc
● Data Function: Frozen Data,Max Demand,etc
● Harmonic: 2~31st and total Harmonic
● Standard&Certificate: IEC; CE;CE-MID; EAC
Front Pannel

Main Function


Dimension

Connect Via CT


Installation

Product Applications

|
Function |
Function description |
Function provide |
|
Measurement of kWh |
Active kWh (positive and negative) |
■ |
|
Reactive kWh (positive andnegative) |
■ |
|
|
A. B, C split phase positive active energy |
■ |
|
|
Measurement of electrical parameters |
U、I |
■ |
|
P、Q、S、PF、F |
■ |
|
|
Measurement of harmonics |
2~31ST Voltage and current |
■
|
|
harmonic |
||
|
LCD Display |
12 bits section LCD display, |
■
|
|
background light |
||
|
Key programming |
3 keys to communication and set |
■
|
|
parameters |
||
|
Pulse output |
Active pulse output |
■ |
|
Multi-tariff and functions |
Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 |
|
|
tariff rates |
□ |
|
|
Max demand and occurrence time |
□ |
|
|
Frozen data on last 48 months, last |
□
|
|
|
90days |
||
|
Date, time |
□ |
|
|
Communication |
Communication interface: RS485, Communication protocol: |
|
|
MODBUS-RTU |
■ |
|
Project |
Performance Parameter |
|||
|
Specification |
3 phase 3 wires |
3 phase 4 wires |
||
|
Measurement |
Voltage |
Reference |
3×100V 、 3×380V |
3×57.7/100V 、 3×220/380V |
|
voltage |
||||
|
Voltage range |
3×100V - 3×450V |
3×57.7/100V - 3×260/450V |
||
|
Consumption |
<10VA(Single phase) |
|||
|
Impedance |
>2MΩ |
|||
|
Accuracy class |
Error±0.2% |
|||
|
Current |
Input current |
3×1(6)A, 3×10(80)A |
||
|
Consumption |
<1VA Single phase rated current |
|||
|
Accuracy class |
Error±0.2% |
|||
|
Power |
Active, reactive, apparent power, error±0.5℅ |
|||
|
Frequency |
45~65Hz,Error±0.2% |
|||
|
Mete ring |
Energy |
Active energy(Accuracy class: 0.5); reactive energy(Accuracy class 2) |
||
|
Clock |
≤0.5s/d |
|||
|
Digit |
Energy pulse output |
1 active photocoupler output |
||
|
signal |
||||
|
pulse |
Width of pulse |
80±20ms |
||
|
Pulse constant |
400imp/kWh,10000imp/kWh(Correspond with the basic current) |
|||
|
communication |
Interface and |
RS485:Modbus RTU |
||
|
Range of communication address |
Modbus RTU:1~ 247; |
|||
|
Baud rate |
1200bps~38400bps |
|||
|
environment |
working temperature |
-25℃~+55℃ |
||
|
Relative humidity |
≤95℅(No condensation) |
|||
|
Relative humidity |
≤95℅(No condensation) |
|||
Shop our new arrivals and best sellers. Click on the image to see product details and click Buy to add a product to cart. We are committed to give you the best buying experience!