AC Data Center Precision Distribution Energy & Environment Monitoring Solution

Jul 15, 2026

Overview

Acrel's AC Data Center Precision Distribution Energy Monitoring Solution delivers comprehensive, high-accuracy sub-metering for modern data center power distribution systems.

 Designed for dual-main supply architectures with UPS redundancy, our solution enables granular energy visibility from main incoming circuits down to individual PDU and server rack levels — supporting both local monitoring and seamless third-party IoT system integration.

Key Features

Precision Sub-Metering at Every Level

· Dual Main Incoming Monitoring: 2× 3-phase circuits (up to 600A) for A/B side power supply tracking

· 3-Phase Branch Circuits

· 1-Phase Branch Circuits

· Class 0.2 Accuracy: Industrial-grade current transformers ensure billing-grade measurement precision

Flexible Integration Architecture

· Local Monitoring Mode: Standalone HMI touchscreen for on-site data display & alarm management

· 3rd-Party Gateway Integration: RS485 Modbus-RTU output compatible with customer-owned IoT gateways

· Acrel IoT Gateway Mode: AWT200 series gateway with 4G/WiFi/Ethernet, supporting MQTT & Modbus-TCP for cloud integration

· Open Protocol: Full Modbus register mapping provided for seamless system integration

Comprehensive Monitoring Capabilities

· Full electrical parameters: V, I, P, Q, S, PF, frequency, energy (kWh)

· 2nd–63rd harmonic analysis & THD monitoring

· 8-channel digital inputs for circuit breaker status monitoring

· 4-channel digital outputs for alarm & control functions

· Optional leakage current & temperature/humidity monitoring


Product Portfolio

Product

Model

Key Specification

Main Metering Module

AMC100-ZA

2-circuit 3-phase AC metering,

3× RS485, 8DI/4DO, harmonic analysis,

integrated power supply output for HMI and sub-metering modules

Multi-Circuit Meter

AMC100-FAK30

10× 3-phase / 30× 1-phase circuits, RS485 Modbus-RTU

AMC100-FAK48

16× 3-phase / 48× 1-phase circuits,

RS485 Modbus-RTU

Current Transformer

AKH-0.66/W-9A/B

50A/50mA, Class 0.2, 9mm aperture,

A/B front/back arrangement

HMI Touch Screen

ATP007kT

7-inch centralized display & alarm,

2× RS485, 24VDC

IoT Gateway

AWT200-1E4S Series

4G / WiFi / Ethernet versions available, 4× RS485 downstream, MQTT & Modbus-TCP upstream

 

System Architecture

Dual-Redundant Power Structure

Our solution maps directly to Tier-3/Tier-4 data center designs with A/B side independent mains supplies, UPS systems, and PDU distribution — ensuring full visibility across the entire power chain.

Three Integration Pathways

1. Local Standalone System

· AMC100 series meters + ATP007kT HMI

· Ideal for cabinet-level local monitoring

· No network dependency required

2. Customer IoT Gateway Integration

· AMC100-ZA → Customer's IoT gateway via RS485 Modbus-RTU

· Perfect for clients with existing IoT platforms

· Acrel provides full Modbus protocol documentation

3. Acrel Gateway + Customer Cloud

· AMC100 meters → AWT200 gateway → Customer's cloud platform

· Supports MQTT & Modbus-TCP protocols

· 4G/WiFi/Ethernet connectivity options

Typical Application Scenario

For a standard AC data center cabinet deployment:

· 2× Main incoming 3-phase circuits(600A class) — monitored by AMC100-ZA

· 10× 3-phase outgoing circuits(32A) to 3-phase PDUs — monitored by AMC100-FAK30

· 48× 1-phase outgoing circuits(32A) to single-phase server racks — monitored by AMC100-FAK48

· Centralized HMIfor real-time display, alarm management, and local configuration

Project References

Note: Project references deployed AMC16 series meters, the predecessor platform with equivalent functionality.

Peru Data Center — DC Power System Energy Management

· Client: INDUSTRIA EMALEXA S.A.C (Switchgear Manufacturer)

· Scope: DC data center precision sub-metering with 3rd-party system integration

· Solution: AMC16-FDK48 multi-circuit DC meters + ATP007kT HMI + Hall effect sensors

· Project Value: ~USD 200,000

Philippines Data Center — AC Power System Energy Management

· Client: TOM'ELE-KT POWER SYSTEMS INC

· Scope: AC data center switchgear integrated energy monitoring

· Solution: AMC16-ZA main meter + AMC16-FAK48 multi-circuit meters + ATP007kT HMI

· Project Value: ~USD 100,000

Why Choose Acrel

· IEC & CE Certified: Compliance with international standards for global deployment

· Modular Design: Scalable from single cabinet to full data center rollouts

· Open & Flexible: Multiple integration paths to fit your existing IT/OT infrastructure

· Cost-Effective: High circuit density per module reduces per-point monitoring cost

· Global Support: Technical documentation & protocol mapping provided for system integrators

Ready to optimize your data center energy visibility? Contact our team for a customized solution design tailored to your facility specifications.