Solutions MORE

Acrel Energy Efficiency Management System includes various cloud platforms such as substation operation and maintenance.

Energy Consumption Monitoring Solution of Base Station

It is necessary to measure and monitor electrical parameters and measure energy in AC side of tower base station such as state grid, diesel, air conditioner, lighting, power supply and so on. In DC side, it is necessary to monitor electrical...

Learn more

Energy Metering for PV Systerm

Nowadays, grid companies usually require photovoltaic grid-connected systems to be irreversible , that is the electricity generated by photovoltaic grid-connected systems is consumed by local loads and excess electricity is not allowed to supply to the grid.

Learn more

Cloud Platform For Power IoT

Acrel loT Energy Management System is a comprehensive system including the functions like real-time electricity parameters monitoring,in-time fault alarm processing and remote control of loT devices which could support all the Acrel products connected with...

Learn more

2003

Year Established

1700+

Total Employees

120+

Service Country

80000+

Servicing Customers

310+

Capital (Million us $)

Projects

Application of DC energy meter in Photovoltaic battery project in Italy

Application of DC energy meter in Photovoltaic battery project in Italy

Abstract: With more and more global energy demand, and under the premise of advocating environmental protection, solar photovoltaic power generation will definitely occupy a major position in the world energy consumption in the 21st century. This paper mainly introduces the application of Acrel DC energy meter in a solar panel company in Italy.Acrel DJSF1352-RN DC energy meter is mainly used for measuring and monitoring of DC signal equipment such as batteries on the DC side of the PV project. 1. Project Overview     This project is for the application of battery monitoring in Italian photovoltaic industry, mainly using our company’s DC energy meter DJSF1352-RN, DC voltage sensor ACTDS-DV and shunt to monitor and measure 1300V battery. 2.Introduction of DC Energy Meter Product     Acrel DC energy meter DJSF1352-RN is designed for DC screen, solar power supply, telecom base station, charging pile and other applications. This series of meters can measure voltage, current, power, forward and reverse energy in DC system.Can be used for local display, and can be connected with industrial control equipment, computer, measurement and control system.At the same time, it has a variety of peripheral interface functions for users to choose: RS 485 communication interface, modbus-RTU protocol;With relay alarm output, switching input/output.According to different requirements, through the meter’s panel buttons, to set and control the ratio, communication. 3.Model Description 4.Technical Parameters 5. Wiring 6. Photos on Site  

ACREL ASJ earth leakage relay’s Application in Philippine mine

ACREL ASJ earth leakage relay’s Application in Philippine mine

Abstract: Ground fault protection for electrical circuits, equipment and electrical fire accidents caused by ground fault currents are increasingly becoming a daily necessity. For the main energy-consuming nodes on the user side, a residual current relay is designed and installed to monitor the residual current status of each energy-using circuit in real time. Through real-time monitoring of energy use and related power parameters, the safety, reliability and maintenance efficiency of energy use are improved, the labor cost of maintenance is reduced, and the unattended monitoring of residual current is realized. Through the real-time monitoring of energy use, data collection and alarm, the residual current in the power distribution system is monitored, and the ground fault protection of the user's electrical circuit is provided to prevent fire accidents and personal electric shock accidents caused by residual current. Here is a brief introduction to the application of our company's ASJ earth leakage relay in the Philippine mine.   1.Project Overview    The mine factory is located in the Philippines, because the current is very big, electricity supply for mine is special , customers hope that through in the power distribution ark installation of residual current relay to residual current monitoring line, and hope that can be displayed on the display panel real-time monitoring of residual current value rather than setting the ratio of residual current value, the ratio can reach 80% when the residual current relay immediately report to the police. Acrel ASJ10-LD1A with residual current transformer, successfully solve the customer's on-site residual current monitoring requirements. Due to the large current on site, we have communicated for many times on the selection of residual current transformer, and selected the most appropriate residual current transformer for the customer based on copper bar and current specifications.   ASJ Series Residual Current Relay     ASJ series current action relays can be combined with low-voltage power supplies or low-voltage contactor to form a combined power supply current protection, mainly used for AC 50Hz, voltage and below TT400V devices and TN system piping, in addition to ground fault protection for electrical circuits to prevent ground faults Common equipment damages and electrical failures caused by this can also prevent the danger of personal electric shock and provide direct contact protection.     The product meets the requirements of GB/T 22387-2016 "Catalyst Current Relay". ASJ series sanitary current relays integrate line over-voltage and under-voltage protection functions and automatic additional functions for normal voltage. The product is small in size, high in precision, flexible in structure and easy to install. It is a safety protection device in the field of civil construction   Model description Technical features Note 3:ASJ10L-LD1A rated residual action current I N is 10mA-30A continuously adjustable; Note 4:ASJ10L-LD1A limit non-driving Time N is 0-10S continuously adjustable.   Types of Products Note1:The function of setting for relay means that you can set the initialization and the output of the relay by yourself, which is acted by the dial switch on the panel; the specific setting guide can be found from the table 5.  Note2:OPTIONAL FUNCTION C: RTU Communication RS485, Model ASJ10L-LD1A/C Model Selection of Residual Current Relay 5.Installation picture Summary    ASJ series residual current relay has a very high performance-price ratio. As an advanced intelligent and digital residual current monitoring instrument, the residual current relay has been widely used in the incoming line or single-phase or three-phase of the household sub-box of civil buildings. Electric equipment in the power distribution line.    Bibliography 1.Solutions For Enterprise Micro-grid System 2021.04      

About the company

Acrel Co., Ltd. [Stock Code : 300286. SZ] is a high-tech enterprise which concentrates on research, production, sales and services. It mainly provides systemic solutions of energy efficiency management and electrical safety for users. Acrel has equipped with the complete production lines from cloud platform software to sensors. Until now, it has more than 8000 sets systemic solutions used in China to help users realizing energy visual management ,supplying energy data services and improving electrical efficiency and safety.

News & Blogs
Capacitor Cabinet Bulging & Power Factor Penalties? Acrel ANSVG Solves

10-23-2026

Capacitor Cabinet Bulging & Power Factor Penalties? Acrel ANSVG Solves "PV Aftereffect" at Source

Case Study · PV Aftereffect Installing photovoltaic systems is intended to save energy and cut operating costs. But after grid connection, many industrial users suffer a sharp drop in power factor and heavy power-factor adjustment penalties month after month. In one Shanghai food seasoning factory, 13 of 40 capacitors bulged and failed completely. The site adopted the Acrel ANSVG static var generator — turning power-factor penalties into rewards within just over one month. The "Sweet Burden" Brought by PV Systems The seasoning manufacturer installed on-site solar PV systems in 2026. Solar power is a great green-energy solution, yet several electrical issues emerged after grid synchronisation. The plant's local consumption load is relatively small, so most generated solar power cannot be consumed on site: the active power drawn from the utility transformer decreased significantly while reactive power remained high. During peak sunlight hours, the power factor of two 1600 kVA transformers dropped to around 0.5 and 0.3 — field measurements recorded values as low as 0.37 and 0.49. 0.37 / 0.49 power factor measured at the plant 2 × 1600 kVA transformers affected by low PF 13 / 40 capacitors bulged & failed +2% bill increase per 0.01 PF below 0.90 What does a power factor of 0.3 or 0.5 mean? Utility regulations impose surcharges when the monthly average power factor falls below 0.90. For every 0.01 reduction in power factor, the electricity bill increases by 2%. This results in unnecessary monthly expenses and forces the whole distribution system to operate under unhealthy conditions. Before retrofit — power factor 0.37 on the existing controller Before retrofit — power factor 0.49 on the existing controller ANSVG units on site A New Solution: Acrel ANSVG Static Var Generator Traditional SVC capacitor compensation cabinets rely on mechanical switching of capacitors. They respond slowly, compensate only in steps, and risk harmonic resonance amplification — capacitors easily overheat, bulge and burn out under such conditions. Capacitor banks cannot fully resolve the PV aftereffect. The Acrel ANSVG static var generator offers more suitable compensation technology for PV-connected sites: it injects controllable reactive current into the grid in real time, delivering stepless, bidirectional, millisecond-level compensation. Fast Response Response time < 5 ms, tracking load fluctuations instantly and maintaining power factor above 0.95 continuously. Wide Compensation Range Continuous adjustment between inductive and capacitive modes — compensates reactive power or absorbs excess reactive power generated by PV systems. Harmonic Mitigation Suppresses selected harmonic orders while compensating reactive power, protecting distribution equipment. Flexible Installation Modular design with independent operation. A single-unit fault will not shut down the whole system — easy maintenance, high reliability. Centralized Monitoring Large touchscreen displays real-time readings of power factor, current, harmonics and other electrical parameters for straightforward status monitoring. ANSVG cabinet installation ANSVG units in the distribution room Project Implementation: 4 × 150 kVar ANSVG in Parallel According to on-site load analysis and compensation requirements, Acrel designed a parallel ANSVG solution for this factory. Each of the two 1600 kVA transformers is equipped with 2 units of 150 kVar ANSVG, 4 units in total, replacing the original SVC capacitor compensation cabinet. Transformer #1 — 2 × 150 kVar ANSVG provide linear real-time reactive compensation and stabilise power factor above 0.95. Transformer #2 — 2 × 150 kVar ANSVG eliminate utility power-factor penalties. Project Results: Power Factor from 0.47 to 1.00 — Penalties Turned into Rewards Field data recorded by the ANSVG touchscreen shows remarkable results. Before retrofit, the load-side power factor of Unit 1 was 0.47; after commissioning, the grid-side power factor reached 1.00. Unit 2 saw the load-side power factor rise from 0.60 up to 1.00 on the grid side. Before · Load Side 0.47 Unit 1 → After · Grid Side 1.00 Unit 1 · 2026-08-03 Before · Load Side 0.60 Unit 2 → After · Grid Side 1.00 Unit 2 · 2026-08-03 The utility invoice shows tangible economic benefits. According to the official power bill of July 2026: 0.97 Metering point #1 — actual PF (requirement 0.90), rewarded PEN 674.87 0.99 Metering point #2 — actual PF (requirement 0.90), rewarded PEN 1,063.53 ≈ PEN 21,000 estimated annual saving on power-factor charges PEN 1,738.40 total monthly power-factor reward — heavy monthly penalties eliminated, PV benefits fully retained. Official utility bill — power-factor adjustment charge: from heavy penalty to monthly reward Results at a Glance Before ANSVG After ANSVG Grid-side power factor 0.47 / 0.60 1.00 Monthly power-factor charge Heavy penalty Reward PEN 1,738.40 Capacitor failures 13 of 40 bulged Eliminated Estimated annual saving — ≈ PEN 21,000 Additional long-term benefits include eliminating capacitor bulging failures, transformer loss reduction and line energy saving. Project acceptance certificate — grid-side PF stabilised at 0.99 ANSVG touchscreen — before vs after comparison Certified Technology Multiple invention patents, software copyrights, utility-model and design patents The Acrel ANSVG series holds multiple authorised invention patents, software copyrights, utility-model and design patents, ensuring reliable quality for every delivered unit. Get a Quote for Your PV Site Tell us your transformer capacity and power-factor situation — we recommend the right ANSVG configuration with price. WhatsApp Mia mia@acrel.cn Mia · Market Manager for Peru, AcrelPhone / WhatsApp: +86 187 2109 7719 · Website: www.acrel.pe .acl-news{--brand:#429A42;--brand-dark:#357A36;--brand-light:#EAF4EA;--blue:#3175AF;--ink:#2A2A2A;--muted:#5F656D;--line:#E8EAEC;font-family:'Noto Sans','ABeeZee',Arial,sans-serif;color:var(--ink);line-height:1.7;background:#fff;font-size:15px} .acl-news *{box-sizing:border-box} .acl-news img{max-width:100%;display:block} .acl-news .acl-wrap{max-width:840px;margin:0 auto;padding:0 20px} .acl-news section{position:relative;padding:22px 0} .acl-news p{color:var(--muted);margin:0 0 13px} .acl-news p b{color:var(--ink);font-weight:700} .acl-news .acl-h2{display:block;font-size:20px!important;font-weight:800;line-height:1.35;margin:0 0 10px!important;position:static!important;float:none!important;color:var(--ink)} .acl-news .acl-lead{font-size:15px;color:var(--muted);margin:0 0 16px} /* 导语卡 */ .acl-news .acl-intro{background:linear-gradient(135deg,#F3F9F3,#FFFFFF);border:1px solid var(--line);border-left:3px solid var(--brand);border-radius:8px;padding:16px 20px;margin:0 0 6px} .acl-news .acl-intro p{font-size:15px;margin:0;color:var(--ink)} .acl-news .acl-intro p b{color:var(--brand-dark)} /* 小标签 */ .acl-news .acl-kicker{display:inline-flex;align-items:center;font-size:11px;font-weight:800;letter-spacing:.12em;text-transform:uppercase;color:var(--brand);background:var(--brand-light);border-radius:999px;padding:5px 12px;margin-bottom:10px} /* 数字条 */ .acl-news .acl-stats{display:grid;grid-template-columns:repeat(4,1fr);gap:10px;margin:14px 0} .acl-news .acl-stat{background:#fff;border:1px solid var(--line);border-radius:8px;padding:12px 14px;text-align:center;box-shadow:0 3px 10px rgba(42,42,42,.04)} .acl-news .acl-stat .v{font-size:20px;font-weight:800;color:var(--brand);line-height:1.25} .acl-news .acl-stat .l{font-size:11.5px;color:var(--muted);margin-top:3px;line-height:1.4} /* 图片 */ .acl-news .acl-fig{margin:14px 0} .acl-news .acl-fig img{width:100%;border-radius:8px} .acl-news .acl-fig .acl-caption{font-size:12px;color:var(--muted);text-align:center;margin-top:7px} .acl-news .acl-fig2{display:grid;grid-template-columns:1fr 1fr;gap:12px;margin:14px 0} .acl-news .acl-fig2 img{width:100%;border-radius:8px} .acl-news .acl-fig2 .acl-caption{font-size:12px;color:var(--muted);text-align:center;margin-top:6px} /* 卖点绿条 */ .acl-news .acl-feats{display:grid;grid-template-columns:1fr 1fr;gap:10px;margin:12px 0} .acl-news .acl-feat{background:#fff;border:1px solid var(--line);border-left:3px solid var(--brand);border-radius:8px;padding:11px 15px} .acl-news .acl-feat .t{font-size:13.5px;font-weight:800;margin-bottom:3px} .acl-news .acl-feat p{font-size:12.5px;margin:0;line-height:1.55} /* 前后对比 */ .acl-news .acl-ba{display:grid;grid-template-columns:1fr auto 1fr;gap:12px;align-items:stretch;background:var(--brand-light);border-radius:8px;padding:14px 16px;margin:14px 0} .acl-news .acl-bab{background:#fff;border-radius:8px;padding:14px 16px;text-align:center} .acl-news .acl-bab .p{font-size:11px;font-weight:800;letter-spacing:.08em;text-transform:uppercase;color:var(--muted);margin-bottom:8px} .acl-news .acl-bab .n{font-size:30px;font-weight:800;line-height:1.1} .acl-news .acl-bab.before .n{color:#C0392B} .acl-news .acl-bab.after .n{color:var(--brand)} .acl-news .acl-bab .d{font-size:11.5px;color:var(--muted);margin-top:5px} .acl-news .acl-arrow{align-self:center;font-size:22px;font-weight:800;color:var(--brand)} /* 结果统计 */ .acl-news .acl-results{display:grid;grid-template-columns:repeat(3,1fr);gap:10px;margin:14px 0} .acl-news .acl-result{background:#fff;border:1px solid var(--line);border-top:3px solid var(--brand);border-radius:8px;padding:14px;text-align:center} .acl-news .acl-result .v{font-size:22px;font-weight:800;color:var(--brand);line-height:1.2} .acl-news .acl-result .l{font-size:11.5px;color:var(--muted);margin-top:4px;line-height:1.45} /* 表格 */ .acl-news .acl-tblscroll{overflow-x:auto;-webkit-overflow-scrolling:touch;background:#fff;border:1px solid var(--line);border-radius:8px;margin:12px 0} .acl-news .acl-table{width:100%;min-width:520px;border-collapse:collapse} .acl-news .acl-table th{background:var(--brand);color:#fff;font-size:13px;font-weight:800;text-align:left;padding:10px 14px;white-space:nowrap} .acl-news .acl-table td{font-size:13px;padding:10px 14px;border-bottom:1px solid var(--line);vertical-align:top;color:var(--muted)} .acl-news .acl-table td:first-child{font-weight:700;color:var(--ink)} .acl-news .acl-table tr:last-child td{border-bottom:none} /* 提示条 */ .acl-news .acl-note{font-size:14px;color:var(--brand-dark);background:var(--brand-light);border-left:3px solid var(--brand);border-radius:6px;padding:11px 16px;margin:12px 0} .acl-news .acl-note b{color:var(--brand-dark)} /* 背书 */ .acl-news .acl-cert{margin:14px 0} /* Contact */ .acl-news .acl-contact{text-align:center;border-top:3px solid var(--brand-light);margin-top:6px} .acl-news .acl-contact .acl-h2{font-size:18px!important;margin-bottom:4px!important} .acl-news .acl-ctarow{display:flex;gap:12px;justify-content:center;flex-wrap:wrap;margin-top:6px} .acl-news .acl-cta{display:inline-flex;align-items:center;gap:8px;background:var(--brand);color:#fff;font-size:13.5px;font-weight:800;text-decoration:none;border-radius:6px;padding:10px 20px} .acl-news .acl-cta:hover{background:var(--brand-dark)} .acl-news .acl-cta.mail{background:#fff;color:var(--brand-dark);border:1px solid var(--brand)} .acl-news .acl-cta svg{width:15px;height:15px} .acl-news .acl-contact .acl-meta{font-size:12px;color:var(--muted);margin-top:12px;line-height:1.8} @media screen and (max-width:640px){ .acl-news section{padding:18px 0} .acl-news .acl-wrap{padding:0 14px} .acl-news .acl-stats{grid-template-columns:repeat(2,1fr)} .acl-news .acl-feats{grid-template-columns:1fr} .acl-news .acl-fig2{grid-template-columns:1fr} .acl-news .acl-results{grid-template-columns:1fr} .acl-news .acl-ba{grid-template-columns:1fr} .acl-news .acl-arrow{text-align:center;transform:rotate(90deg)} .acl-news .acl-h2{font-size:17px!important} }

READ MORE
Acrel to Attend 5th Engineering Exhibition & Conference 2026 in Malaysia

09-03-2026

Acrel to Attend 5th Engineering Exhibition & Conference 2026 in Malaysia

     Acrel is ready to meet partners and industry practitioners at the 5th Engineering Exhibition & Conference 2026, which will run from September 22 to 25 at the Kuala Lumpur Convention Centre, Malaysia.    We will set up our booth No.1G107 and bring our mature microgrid energy efficiency solutions for Southeast Asian market visitors.    Our display covers photovoltaic & energy storage monitoring, commercial and industrial power distribution system, energy consumption management, power quality improvement and digital electrical safety products.    Our onsite technical team will communicate facetoface with local EPC contractors, factory owners, property managers and energy project investors. We will discuss practical pain points of energy saving, power safety and intelligent power monitoring for factories, commercial buildings and solarstorage projects in Malaysia and Southeast Asia.     If you plan to visit the exhibition, welcome to stop by our booth to exchange ideas and explore longterm business cooperation.     Contact Mia Peru Market Manager - Acrel  Email: mia@acrel.cn  WhatsApp: +86 18721097719  We are available for pre-show consultation and appointment. We look forward to meeting you in Kuala Lumpur.

READ MORE
Multi-Circuit Energy Meters for Restaurants: 300 Burger King Sites in France

10-30-2026

Multi-Circuit Energy Meters for Restaurants: 300 Burger King Sites in France

Case Study · Restaurant Chain A French energy service provider is sub-metering 35 kitchen and HVAC loads in every Burger King restaurant it retrofits — using Acrel multi-circuit meters and LoRaWAN gateways. Fifty stores are live, 60 more were ordered in late 2025, and another 30 in 2026. Published October 2026 · 6 min read 01The Brief: 35 Loads, One Main Meter Brio Energy, a French energy-management company that runs monitoring programmes for restaurant and hotel chains, was preparing a preventive-maintenance and energy-efficiency retrofit for Burger King restaurants in and around Paris. The target: roughly 300 sites, with lighting, extraction fans, ventilation, fryers, broilers, cold rooms and rooftop units on the list. The problem was visibility. Each restaurant had only an incoming main meter, so nobody could tell which piece of equipment was drawing what. The retrofit needed sub-metering — and it had to work inside the constraints of an existing restaurant: 35 single-phase loads per storeLighting circuits, kitchen equipment, ventilation and cold rooms, all on one distribution board. Very little panel spaceThe retrofit had to fit into existing cabinets, not a new electrical room. Long cable runsSome circuits sat 6 to 8 metres apart, ruling out a single centrally placed meter. Very small currentsSome lighting and sign circuits drew as little as 0.02 A. Harmonics, at least at a basic levelPreventive maintenance needed a simple view of harmonic distortion, not a full power-quality analyser. The enquiry reached Acrel through Google: Brio Energy's project lead, Sylvain Gully, searched for a multi-circuit energy meter with current transformers included, and asked whether Acrel had a distributor in France. There wasn't one yet — so the project was handled directly, with online technical sessions between Brio's team and Acrel engineers. 02The Hardware: A Multi-Circuit Meter Built for Tight Panels Two meter variants were selected: ADW210-D10-4S and ADW210-D16-4S, both DIN-rail multi-circuit meters. Several units are installed per restaurant, each covering a group of circuits with its own current transformers. CT ratios were matched to the load: 5 A for lighting and small power, 30 A for fryers and ventilation, 250 A for rooftop units. Measured accuracy is 1% across 10–120% of the CT rating. ADW210 multi-circuit meter with CTs AWT100-CEHW LoRaWAN gateway Data leaves the panel over RS485. An AWT100-CEHW gateway converts the Modbus RTU data to LoRaWAN, which keeps cabling short inside the restaurant and avoids pulling new network cable through ceilings. A Milesight gateway on site forwards the data over 4G or Wi-Fi to Brio Energy's own platform, where store managers and the maintenance team see the readings. At a glance Specification Meter Acrel ADW210-D10-4S / ADW210-D16-4S, DIN-rail, multi-circuit Current transformers 5 A / 30 A / 250 A, matched per circuit Accuracy 1% (10–120% of CT rating) Local communication RS485, Modbus RTU Uplink AWT100-CEHW LoRaWAN gateway → Milesight gateway → 4G / Wi-Fi Platform Brio Energy monitoring platform A completed retrofit panel: several ADW210 units, labelled by circuit group, share the existing cabinet 03The Rollout: Ten Stores First, Then Sixty, Then Thirty The project did not start with a 300-store order. It started with a technical conversation, then a small batch. Mar–Apr 2025 Requirements and site survey. Load list, panel dimensions and circuit distances reviewed; meter and CT selection agreed. May–Jul 2025 Two architecture options discussed with Brio Energy. Ten stores equipped as a pilot, with online Q&A sessions on installation and platform integration. Oct–Nov 2025 Batch order for 60 restaurants after the pilot data was reviewed. 2026 30 more restaurants equipped; another 30 expected. Phase one of the programme — 50 stores — completed. Installation work in an existing restaurant electrical room 04What the Data Delivers Once every circuit is metered, the platform does more than display kWh. Brio Energy uses the readings for four things: 01 Online store management Consumption is read remotely instead of copied by hand during site visits — fewer manual readings, more reliable data. 02 Energy performance management Each store's consumption is tracked in real time, so high-consumption equipment can be adjusted before it becomes a cost problem. 03 KPI comparison Consumption per unit area and regional averages let the chain compare stores of different sizes on the same basis. 04 Basis for retrofit decisions Readings from air conditioning, signage, lighting and heaters identify where an upgrade pays back fastest — and the platform calculates the payback period. The four outcomes Brio Energy tracks across the estate For a restaurant, the practical value shows up in preventive maintenance. A fryer drawing more current than its usual profile, or a cold room compressor cycling differently, is visible in the circuit data before it becomes a breakdown. That is the difference between reacting to failures and scheduling service around them. 05Why This Matters for Restaurant Chains in Peru and Latin America The French rollout is a large-scale example of a problem that looks the same in Lima, Bogotá or Santiago: a chain with dozens of sites, one meter per location, and no way to tell which equipment is wasting energy. Rising tariffs and aging kitchen equipment make the gap more expensive every year. The same architecture scales down to a single site. A 20–40 circuit restaurant can start with two or three ADW210 meters and one AWT100 gateway, keep the existing panel, and send data to a local platform or a cloud dashboard. No new cable trays, no rewiring of the kitchen. For distributors and system integrators in South America, the retrofit model is repeatable: survey the panel, match CTs to each circuit, install meters during a maintenance window, and let the platform do the reporting. Acrel supports OEM and private-label programmes for partners building this service locally. Quick Answers Can the meter handle very small loads? Yes — small lighting and signage circuits were measured with 5 A CTs in this project, while fryers and rooftop units used 30 A and 250 A CTs. Matching the CT to the circuit is the key step. Will it fit an existing restaurant panel? ADW210 is a DIN-rail meter, and several circuits share one unit. In this project the meters went into the cabinets already on site, with no new electrical room. Can the data go to our own platform? Yes. The meters output Modbus RTU over RS485; the AWT100-CEHW gateway forwards it over LoRaWAN, and the data can be routed to a third-party or in-house platform. Planning a Multi-Site Retrofit? Send us your load list and panel photos — we will propose a meter and CT configuration for your restaurants. WhatsApp Mia mia@acrel.cn Mia · Market Manager for Peru, AcrelPhone / WhatsApp: +86 187 2109 7719 · Website: www.acrel.pe .acl-news{--brand:#429A42;--brand-dark:#357A36;--brand-light:#EAF4EA;--blue:#3175AF;--ink:#2A2A2A;--muted:#5F656D;--line:#E8EAEC;font-family:'Noto Sans','ABeeZee',Arial,sans-serif;color:var(--ink);line-height:1.7;background:#fff;font-size:15px} .acl-news *{box-sizing:border-box} .acl-news img{max-width:100%;display:block} .acl-news .acl-wrap{max-width:840px;margin:0 auto;padding:0 20px} .acl-news section{position:relative;padding:20px 0} .acl-news p{color:var(--muted);margin:0 0 13px} .acl-news p b{color:var(--ink);font-weight:700} .acl-news .acl-h2{display:block;font-size:20px!important;font-weight:800;line-height:1.35;margin:0 0 10px!important;position:static!important;float:none!important;color:var(--ink)} .acl-news .acl-num{display:inline-block;font-size:12px;font-weight:800;color:var(--brand);background:var(--brand-light);border-radius:4px;padding:2px 7px;margin-right:9px;vertical-align:2px;letter-spacing:.04em} .acl-news .acl-kicker{display:inline-flex;align-items:center;font-size:11px;font-weight:800;letter-spacing:.12em;text-transform:uppercase;color:var(--brand);background:var(--brand-light);border-radius:999px;padding:5px 12px;margin-bottom:10px} .acl-news .acl-standfirst{font-size:17px;line-height:1.55;color:var(--ink);margin:0 0 10px} .acl-news .acl-byline{font-size:12px;color:#9AA0A6;border-bottom:1px solid var(--line);padding-bottom:16px} /* bullets */ .acl-news .acl-bullets{margin:14px 0} .acl-news .acl-bullet{position:relative!important;padding:10px 0 10px 18px;border-top:1px solid var(--line)} .acl-news .acl-bullet:before{content:"";position:absolute;left:0;top:17px;width:6px;height:6px;border-radius:50%;background:var(--brand)} .acl-news .acl-bullet b{display:block;font-size:14px;color:var(--ink);margin-bottom:2px} .acl-news .acl-bullet span{display:block;font-size:13px;color:var(--muted);line-height:1.6} /* images */ .acl-news .acl-fig{margin:14px 0} .acl-news .acl-fig img{width:100%;border-radius:8px} .acl-news .acl-fig .acl-caption{font-size:12px;color:var(--muted);text-align:center;margin-top:7px} .acl-news .acl-fig2{display:grid;grid-template-columns:1fr 1fr;gap:12px;margin:14px 0} .acl-news .acl-fig2 img{width:100%;border-radius:8px;background:#F7F8F7} .acl-news .acl-fig2 .acl-caption{font-size:12px;color:var(--muted);text-align:center;margin-top:6px} /* table */ .acl-news .acl-tblscroll{overflow-x:auto;-webkit-overflow-scrolling:touch;background:#fff;border:1px solid var(--line);border-radius:8px;margin:12px 0} .acl-news .acl-table{width:100%;min-width:480px;border-collapse:collapse} .acl-news .acl-table th{background:var(--brand);color:#fff;font-size:13px;font-weight:800;text-align:left;padding:10px 14px;white-space:nowrap} .acl-news .acl-table td{font-size:13px;padding:10px 14px;border-bottom:1px solid var(--line);vertical-align:top;color:var(--muted)} .acl-news .acl-table td:first-child{font-weight:700;color:var(--ink);white-space:nowrap} .acl-news .acl-table tr:last-child td{border-bottom:none} /* timeline */ .acl-news .acl-timeline{margin:14px 0;border-left:2px solid var(--brand-light);padding-left:18px} .acl-news .acl-tl{position:relative!important;padding:0 0 16px 0} .acl-news .acl-tl:before{content:"";position:absolute;left:-25px;top:6px;width:9px;height:9px;border-radius:50%;background:var(--brand);border:2px solid #fff} .acl-news .acl-tl .d{font-size:11.5px;font-weight:800;letter-spacing:.06em;text-transform:uppercase;color:var(--brand);margin-bottom:2px} .acl-news .acl-tl .t{font-size:13.5px;color:var(--muted);line-height:1.6} /* value grid */ .acl-news .acl-valuegrid{display:grid;grid-template-columns:1fr 1fr;gap:10px;margin:12px 0} .acl-news .acl-value{background:#fff;border:1px solid var(--line);border-radius:8px;padding:13px 15px} .acl-news .acl-value .n{font-size:11px;font-weight:800;letter-spacing:.08em;color:var(--brand)} .acl-news .acl-value .t{font-size:14px;font-weight:800;color:var(--ink);margin:3px 0 4px} .acl-news .acl-value p{font-size:12.5px;margin:0;line-height:1.6} /* FAQ */ .acl-news .acl-faq{margin:10px 0} .acl-news .acl-q{border-top:1px solid var(--line);padding:12px 0} .acl-news .acl-q .t{font-size:14px;font-weight:800;color:var(--ink);margin-bottom:3px} .acl-news .acl-q p{font-size:13px;margin:0;line-height:1.65} /* contact */ .acl-news .acl-contact{text-align:center;border-top:3px solid var(--brand-light);margin-top:6px} .acl-news .acl-contact .acl-h2{font-size:18px!important;margin-bottom:4px!important} .acl-news .acl-ctarow{display:flex;gap:12px;justify-content:center;flex-wrap:wrap;margin-top:8px} .acl-news .acl-cta{display:inline-flex;align-items:center;gap:8px;background:var(--brand);color:#fff;font-size:13.5px;font-weight:800;text-decoration:none;border-radius:6px;padding:10px 20px} .acl-news .acl-cta:hover{background:var(--brand-dark)} .acl-news .acl-cta.mail{background:#fff;color:var(--brand-dark);border:1px solid var(--brand)} .acl-news .acl-cta svg{width:15px;height:15px} .acl-news .acl-contact .acl-meta{font-size:12px;color:var(--muted);margin-top:12px;line-height:1.8} @media screen and (max-width:640px){ .acl-news .acl-wrap{padding:0 14px} .acl-news section{padding:16px 0} .acl-news .acl-h2{font-size:17px!important} .acl-news .acl-standfirst{font-size:15px} .acl-news .acl-fig2{grid-template-columns:1fr} .acl-news .acl-valuegrid{grid-template-columns:1fr} }

READ MORE
Acrel to attend Electric & Power Indonesia 2026 in Jakarta

08-24-2026

Acrel to attend Electric & Power Indonesia 2026 in Jakarta

ELECTRIC & POWER INDONESIA 2026 will take place from September 2 to 5 at Jakarta International Expo, Kemayoran. Acrel will showcase our complete Micro-grid Energy Efficiency Solutions at Booth A2-2021.                We will display a full portfolio including PV & bidirectional energy meters, power quality equipment, energy management SCADA system, EV charging metering units and electrical safety devices, all compliant with IEC standards for Indonesia power grid.     Our overseas technical and sales team will be on site to offer customized solution consultation, local project reference and business discussion for EPC contractors, factory owners, electrical distributors and power designers.     With growing demand for solar PV, energy storage and industrial energy-saving in Indonesia, Acrel keeps providing reliable digital power solutions to support local lowcarbon transition. We sincerely invite all industry partners to visit our booth A2-2021 for facetoface communication.     Show Info Date: Sep 02-05, 2026 Venue: Jakarta International Expo, Kemayoran Booth No.: A2-2021  

READ MORE

Our Partners